Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.229
Filtrar
1.
Int Arch Otorhinolaryngol ; 28(2): e203-e210, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38618599

RESUMO

Introduction Jet aircraft pilots are exposed to huge pressure variation during flight, which affect physiological functions as systems, such as the respiratory system. Objectives The objective of the present investigation was to evaluate inflammatory changes of paranasal sinuses of jet aircraft pilots before and after a jet aircraft training program, using multislice computed tomography (CT), in comparison with a group of nonairborne individuals with the same age, sex, and physical health conditions. A second objective of the present study was to assess the association between the ostiomeatal complex obstruction and its anatomical variations. Methods The study group consisted of 15 jet aircraft pilots participating in the training program. The control group consisted of 41 nonairborne young adults. The 15 fighter pilots were evaluated before initiating the training program and after their final approval for the presence of inflammatory paranasal sinus disease. The ostiomeatal complex anatomical variations and obstructions were analyzed in pilots after the training program. Results Jet aircraft pilots presented higher incidence of mucosal thickening in maxillary sinus and anterior ethmoid cells than controls. Prominent ethmoidal bulla showed significant association with obstruction of the osteomeatal complex. Conclusions Jet aircraft pilots present increased inflammatory disease when compared with nonairborne individuals. The presence of a prominent ethmoidal bulla is associated with ostiomeatal complex obstruction.

2.
Eur Radiol ; 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38625613

RESUMO

BACKGROUND: Lung cancer, the second most common cancer, presents persistently dismal prognoses. Radiomics, a promising field, aims to provide novel imaging biomarkers to improve outcomes. However, clinical translation faces reproducibility challenges, despite efforts to address them with quality scoring tools. OBJECTIVE: This study had two objectives: 1) identify radiomics biomarkers in post-radiotherapy stage III/IV nonsmall cell lung cancer (NSCLC) patients, 2) evaluate research quality using the CLEAR (CheckList_for_EvaluAtion_of_Radiomics_research), RQS (Radiomics_Quality_Score) frameworks, and formulate an amalgamated CLEAR-RQS tool to enhance scientific rigor. MATERIALS AND METHODS: A systematic literature review (Jun-Aug 2023, MEDLINE/PubMed/SCOPUS) was conducted concerning stage III/IV NSCLC, radiotherapy, and radiomic features (RF). Extracted data included study design particulars, such as sample size, radiotherapy/CT technique, selected RFs, and endpoints. CLEAR and RQS were merged into a CLEAR-RQS checklist. Three readers appraised articles utilizing CLEAR, RQS, and CLEAR-RQS metrics. RESULTS: Out of 871 articles, 11 met the inclusion/exclusion criteria. The Median cohort size was 91 (range: 10-337) with 9 studies being single-center. No common RF were identified. The merged CLEAR-RQS checklist comprised 61 items. Most unreported items were within CLEAR's "methods" and "open-source," and within RQS's "phantom-calibration," "registry-enrolled prospective-trial-design," and "cost-effective-analysis" sections. No study scored above 50% on RQS. Median CLEAR scores were 55.74% (32.33/58 points), and for RQS, 17.59% (6.3/36 points). CLEAR-RQS article ranking fell between CLEAR and RQS and aligned with CLEAR. CONCLUSION: Radiomics research in post-radiotherapy stage III/IV NSCLC exhibits variability and frequently low-quality reporting. The formulated CLEAR-RQS checklist may facilitate education and holds promise for enhancing radiomics research quality. CLINICAL RELEVANCE STATEMENT: Current radiomics research in the field of stage III/IV postradiotherapy NSCLC is heterogenous, lacking reproducibility, with no identified imaging biomarker. Radiomics research quality assessment tools may enhance scientific rigor and thereby facilitate radiomics translation into clinical practice.

4.
Imaging Sci Dent ; 54(1): 115-120, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38571774

RESUMO

Components derived from an infected lesion within the bone can spread through various passages in the mandible, particularly via the mental foramen. Radiologically, the spread of infection is typically nonspecific and challenging to characterize; however, multislice computed tomography (MSCT) can effectively detect pathological changes in soft tissues and the bone marrow space. This report describes the case of a 55-year-old woman who experienced mental nerve paresthesia due to a periapical infection of the right mandibular second premolar. MSCT imaging revealed increased attenuation around the periapical lesion extending into the mandibular canal and loss of the juxtamental foraminal fat pad. Following endodontic treatment of the tooth suspected to be the source of the infection, the patient's symptoms resolved, and the previous MSCT imaging findings were no longer present. Increased bone marrow attenuation and obliteration of the fat plane in the buccal aspect of the mental foramen may serve as radiologic indicators of inflammation spreading from the bone marrow space.

5.
J Oral Rehabil ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570928

RESUMO

BACKGROUND: Upper oesophageal sphincter (UES) serves as an important anatomical and functional landmark during swallowing. However, the precise UES location before and during swallowing has not been well established. OBJECTIVE: This study aimed to determine upper oesophageal sphincter (UES) location and displacement during swallowing accounting for sex, age, and height in healthy adults using 320-row area detector computed tomography (320-ADCT). METHODS: Ninety-four healthy adults (43 males; 22-90 years) underwent 320-ADCT scanning while swallowing one trial of 10 mL honey thick barium. UES location at bolus hold and at maximum displacement and vertical displacement during swallowing were identified using the coordinates and the section classification of vertebrae (VERT scale). The differences and correlations of UES location and distance in terms of sex, age, and height were analysed using Mann-Whitney U test and Spearman's correlation coefficient. RESULTS: UES locations at bolus hold and at maximum displacement were significantly lower and UES vertical displacement was significantly larger in males than in females (p < .001). UES location at bolus hold became lower with increasing age (r = -.312, p = .002), but the negative correlation was low at maximum displacement (r = -.230, p = .026), resulting in larger vertical distance with ageing. UES locations showed high negative correlation at bolus hold with height (r = -.715, p < .001), and showed moderate negative correlation at maximum displacement with height (r = -.555, p < .001), although this effect was unclear when analysed by sex. CONCLUSION: Males showed lower UES location and larger displacement than females. The impact of age was evident with lower location before swallowing and larger displacement during swallowing. Differences observed by sex were not completely explained by using the VERT scale to adjust for height.

6.
Front Oncol ; 14: 1346124, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559563

RESUMO

Objective: To develop a contrast-enhanced computed tomography (CECT) based radiomics model using machine learning method and assess its ability of preoperative prediction for the early recurrence of hepatocellular carcinoma (HCC). Methods: A total of 297 patients confirmed with HCC were assigned to the training dataset and test dataset based on the 8:2 ratio, and the follow-up period of the patients was from May 2012 to July 2017. The lesion sites were manually segmented using ITK-SNAP, and the pyradiomics platform was applied to extract radiomic features. We established the machine learning model to predict the early recurrence of HCC. The accuracy, AUC, standard deviation, specificity, and sensitivity were applied to evaluate the model performance. Results: 1,688 features were extracted from the arterial phase and venous phase images, respectively. When arterial phase and venous phase images were employed correlated with clinical factors to train a prediction model, it achieved the best performance (AUC with 95% CI 0.8300(0.7560-0.9040), sensitivity 89.45%, specificity 79.07%, accuracy 82.67%, p value 0.0064). Conclusion: The CECT-based radiomics may be helpful to non-invasively reveal the potential connection between CECT images and early recurrence of HCC. The combination of radiomics and clinical factors could boost model performance.

7.
Diagn Interv Imaging ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604894

RESUMO

PURPOSE: The purpose of this study was to compare ultra-low dose (ULD) and standard low-dose (SLD) chest computed tomography (CT) in terms of radiation exposure, image quality and diagnostic value for diagnosing pulmonary arteriovenous malformation (AVM) in patients with hereditary hemorrhagic telangiectasia (HHT). MATERIALS AND METHODS: In this prospective board-approved study consecutive patients with HHT referred to a reference center for screening and/or follow-up chest CT examination were prospectively included from December 2020 to January 2022. Patients underwent two consecutive non-contrast chest CTs without dose modulation (i.e., one ULD protocol [80 kVp or 100 kVp, CTDIvol of 0.3 mGy or 0.6 mGy] and one SLD protocol [140 kVp, CTDIvol of 1.3 mGy]). Objective image noises measured at the level of tracheal carina were compared between the two protocols. Overall image quality and diagnostic confidence were scored on a 4-point Likert scale (1 = insufficient to 4 = excellent). Sensitivity, specificity, positive predictive value and negative predictive value of ULD CT for diagnosing pulmonary AVM with a feeding artery of over 2 mm in diameter were calculated along with their 95% confidence intervals (CI) using SLD images as the standard of reference. RESULTS: A total of 44 consecutive patients with HHT (31 women; mean age, 42 ± 16 [standard deviation (SD)] years; body mass index, 23.2 ± 4.5 [SD] kg/m2) were included. Thirty-four pulmonary AVMs with a feeding artery of over 2 mm in diameter were found with SLD images versus 35 with ULD images. Sensitivity, specificity, predictive positive value, and predictive negative value of ULD CT for the diagnosis of PAVM were 100% (34/34; 95% CI: 90-100), 96% (18/19; 95% CI: 74-100), 97% (34/35; 95% CI: 85-100) and 100% (18/18; 95% CI: 81-100), respectively. A significant difference in diagnostic confidence scores was found between ULD (3.8 ± 0.4 [SD]) and SLD (3.9 ± 0.1 [SD]) CT images (P = 0.03). No differences in overall image quality scores were found between ULD CT examinations (3.9 ± 0.2 [SD]) and SLD (4 ± 0 [SD]) CT examinations (P = 0.77). Effective radiation dose decreased significantly by 78.8% with ULD protocol, with no significant differences in noise values between ULD CT images (16.7 ± 5.0 [SD] HU) and SLD images (17.7 ± 6.6 [SD] HU) (P = 0.07). CONCLUSION: ULD chest CT provides 100% sensitivity and 96% specificity for the diagnosis of treatable pulmonary AVM with a feeding artery of over 2 mm in diameter, leading to a 78.8% dose-saving compared with a standard low-dose protocol.

8.
Eur Radiol ; 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38634876

RESUMO

OBJECTIVES: To distinguish histological subtypes of renal tumors using radiomic features and machine learning (ML) based on multiphase computed tomography (CT). MATERIAL AND METHODS: Patients who underwent surgical treatment for renal tumors at two tertiary centers from 2012 to 2022 were included retrospectively. Preoperative arterial (corticomedullary) and venous (nephrogenic) phase CT scans from these centers, as well as from external imaging facilities, were manually segmented, and standardized radiomic features were extracted. Following preprocessing and addressing the class imbalance, a ML algorithm based on extreme gradient boosting trees (XGB) was employed to predict renal tumor subtypes using 10-fold cross-validation. The evaluation was conducted using the multiclass area under the receiver operating characteristic curve (AUC). Algorithms were trained on data from one center and independently tested on data from the other center. RESULTS: The training cohort comprised n = 297 patients (64.3% clear cell renal cell cancer [RCC], 13.5% papillary renal cell carcinoma (pRCC), 7.4% chromophobe RCC, 9.4% oncocytomas, and 5.4% angiomyolipomas (AML)), and the testing cohort n = 121 patients (56.2%/16.5%/3.3%/21.5%/2.5%). The XGB algorithm demonstrated a diagnostic performance of AUC = 0.81/0.64/0.8 for venous/arterial/combined contrast phase CT in the training cohort, and AUC = 0.75/0.67/0.75 in the independent testing cohort. In pairwise comparisons, the lowest diagnostic accuracy was evident for the identification of oncocytomas (AUC = 0.57-0.69), and the highest for the identification of AMLs (AUC = 0.9-0.94) CONCLUSION: Radiomic feature analyses can distinguish renal tumor subtypes on routinely acquired CTs, with oncocytomas being the hardest subtype to identify. CLINICAL RELEVANCE STATEMENT: Radiomic feature analyses yield robust results for renal tumor assessment on routine CTs. Although radiologists routinely rely on arterial phase CT for renal tumor assessment and operative planning, radiomic features derived from arterial phase did not improve the accuracy of renal tumor subtype identification in our cohort.

9.
Radiol Case Rep ; 19(7): 2650-2653, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38645950

RESUMO

Acute calcific longus colli tendinitis is a differential diagnosis of neck pain. Typical presentation consists in a triad of symptoms including acute onset neck pain, neck stiffness and odynophagia. Computed tomography (CT) is the gold standard for acute calcific longus colli tendinitis diagnosis and the main radiological findings include prevertebral soft tissue swelling and the presence of amorphous calcifications. The case involves a 39-year-old female who presented to the emergency department with acute unilateral cervical pain that resulted in acute calcific longus colli tendinitis.

10.
Skeletal Radiol ; 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38499892

RESUMO

OBJECTIVE: Although there is growing evidence that ultrasonography is superior to X-ray for rib fractures' detection, X-ray is still indicated as the most appropriate method. This has partially been attributed to a lack of studies using an appropriate reference modality. We aimed to compare the diagnostic accuracy of ultrasonography and X-ray in the detection of rib fractures, considering CT as the reference standard. MATERIALS AND METHODS: Within a 2.5-year period, all consecutive patients with clinically suspected rib fracture(s) following blunt chest trauma and available posteroanterior/anteroposterior X-ray and thoracic CT were prospectively studied and planned to undergo thoracic ultrasonography, by a single operator. All imaging examinations were evaluated for cortical rib fracture(s), and their location was recorded. The cartilaginous rib portions were not assessed. CTs and X-rays were evaluated retrospectively. Concomitant thoracic/extra-thoracic injuries were assessed on CT. Comparisons were performed with the Mann-Whitney U test and Fisher's exact test. RESULTS: Fifty-nine patients (32 males, 27 females; mean age, 53.1 ± 16.6 years) were included. CT, ultrasonography, and X-ray (40 posteroanterior/19 anteroposterior views) diagnosed 136/122/42 rib fractures in 56/54/27 patients, respectively. Ultrasonography and X-ray had sensitivity of 100%/40% and specificity of 89.7%/30.9% for rib fractures' detection. Ultrasound accuracy was 94.9% compared to 35.4% for X-rays (P < .001) in detecting individual rib fractures. Most fractures involved the 4th-9th ribs. Upper rib fractures were most commonly overlooked on ultrasonography. Thoracic cage/spine fractures and haemothorax represented the most common concomitant injuries. CONCLUSION: Ultrasonography appeared to be superior to X-ray for the detection of rib fractures with regard to a reference CT.

11.
Abdom Radiol (NY) ; 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38456897

RESUMO

PURPOSE: To evaluate the diagnostic performance of multiphase hepatic CT parameters (non-contrast attenuation, absolute and relative washout ratios [APW and RPW, respectively], and relative enhancement ratio [RER]) and chemical-shift MRI (CS-MRI) for discriminating lipid-poor adrenal adenomas (with non-contrast CT attenuation > 10 HU) from metastases in patients with hepatocellular carcinoma (HCC). METHODS: This retrospective study included HCC patients with lipid-poor adrenal lesions who underwent multiphase hepatic CT between January 2010 and December 2021. For each adrenal lesion, non-contrast attenuation, APW, RPW, RER, and signal-intensity index (SI-index) were measured. Each parameter was compared between adenomas and metastases. The area under the receiver operating characteristic curves (AUCs) and sensitivities to achieve 100% specificity for adenoma diagnoses were determined. RESULTS: 104 HCC patients (78 men; mean age, 71.8 ± 9.6 years) with 63 adenomas and 48 metastases were identified; CS-MRI was performed in 66 patients with 49 adenomas and 21 metastases within one year of CT. Lipid-poor adenomas showed lower non-contrast attenuation (22.9 ± 7.1 vs. 37.9 ± 9.4 HU) and higher APW (40.5% ± 12.8% vs. 23.7% ± 17.4%), RPW (30.0% ± 10.2% vs. 12.4% ± 9.6%), RER (329% ± 152% vs. 111% ± 43.0%), and SI-index (43.3 ± 20.7 vs. 10.8 ± 13.4) than HCC metastases (all p < .001). AUC for non-contrast attenuation, APW, RPW, RER, and SI-index were 0.894, 0.786, 0.904, 0.969, and 0.902, respectively. The sensitivities to achieve 100% specificity were 7.9%, 25.4%, 30.2%, 63.5%, and 24.5%, respectively. Combined RER and APW achieved the highest sensitivity of 73.0%. CONCLUSION: Multiphase hepatic CT allows for better discrimination between lipid-poor adrenal adenomas and metastases relative to CS-MRI, especially when combined with RER and washout parameters.

12.
Abdom Radiol (NY) ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38517545

RESUMO

PURPOSE: To evaluate quantitative and qualitative spermatic cord CT abnormalities and presence of unilateral or bilateral symptomatic scrotal pathology (SSP) at ultrasound. METHODS: This retrospective study included 122 male patients (mean age 47.8 years) undergoing scrotal ultrasound within 24 h of contrast-enhanced CT (n = 85), non-contrast CT (NECT, n = 32) or CT-Urogram (n = 5). CECT quantitative analysis assessed differential cord enhancement using maximum Hounsfield unit measurements. Three fellowship trained body radiologists independently assessed qualitative cord abnormalities for both CECT and NECT. Qualitative and quantitative findings were compared with the presence of SSP. Reader performance, interobserver agreement and reader confidence were assessed for NECT and CECT. Quantitative cutoff points were identified which maximized accuracy, specificity, negative predictive value, and other measures. RESULTS: SSP was present in 36/122 patients (29.5%). Positive cases were unilateral in 30 (83.3%) and bilateral in 6 (16.6%). At quantitative assessment, 25% differential cord enhancement had the highest diagnostic accuracy (88.9%), with 90.5% positive predictive value, 88.4% negative predictive value, 96.8% specificity, and 70.4% sensitivity. At qualitative evaluation, CECT reader performance was excellent (aggregate AUC = 0.86; P < .001); NECT was poorly discriminatory, although remained significant (aggregate AUC = 0.67; P = .002). Readers had significantly higher confidence levels with CECT (P < .001). Qualitative inter-observer agreement was high for both CECT and NECT (ICC = 0.981 and 0.963, respectively). CONCLUSION: Simple quantitative assessment of differential cord enhancement is highly accurate and specific for SSP at CECT. Qualitative abnormalities at CECT and NECT are also both predictors of SSP, however, CECT significantly out-performs non-contrast exams.

13.
Ann Anat ; 254: 152258, 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38490465

RESUMO

INTRODUCTION: The inferior phrenic artery is a paired artery with a variable origin and course, primarily supplying the diaphragm, but also the suprarenal glands, inferior vena cava, stomach, and oesophagus. The aim of this study is to investigate the origin and course of the inferior phrenic arteries on multidetector computed tomography and angiography. MATERIALS AND METHODS: The anatomy of the inferior phrenic artery was analysed on 2449 multidetector computed tomography scans. Three-dimensional reconstructions were made of the main variations. Additionally, the course and branching pattern of the inferior phrenic artery were descriptively analysed in a cohort of 28 angiograms. RESULTS: In 565 (23.1%) cases the inferior phrenic arteries arose as a common trunk and in 1884 (76.9%) cases as individual vessels. The most common origins of a common trunk were the coeliac trunk (n=303; 53.6%) and abdominal aorta (n=255; 45.1%). The most common origins of the right inferior phrenic artery were the coeliac trunk (n=965; 51.2%), abdominal aorta (n=562; 29.8%) and renal arteries (n=214; 11.4%). The most common origins of the left inferior phrenic artery were the coeliac trunk (n=1293; 68.6%) and abdominal aorta (n=403; 21.4%). CONCLUSION: The inferior phrenic artery has a very variable anatomy. The most common origins of the inferior phrenic artery are the coeliac trunk and its branches, the abdominal aorta, and the renal arteries.

15.
Diagn Interv Imaging ; 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38429207

RESUMO

PURPOSE: The purpose of this study was to assess image quality and dose level using a photon-counting CT (PCCT) scanner by comparison with a dual-source CT (DSCT) scanner on virtual monoenergetic images (VMIs) at low energy levels. MATERIALS AND METHODS: A phantom was scanned using a DSCT and a PCCT with a volume CT dose index of 11 mGy, and additionally at 6 mGy and 1.8 mGy for PCCT. Noise power spectrum and task-based transfer function were evaluated from 40 to 70 keV on VMIs to assess noise magnitude and noise texture (fav) and spatial resolution on two iodine inserts (f50), respectively. A detectability index (d') was computed to assess the detection of two contrast-enhanced lesions according to the energy level used. RESULTS: For all energy levels, noise magnitude values were lower with PCCT than with DSCT at 11 and 6 mGy, but greater at 1.8 mGy. fav values were higher with PCCT than with DSCT at 11 mGy (8.6 ± 1.5 [standard deviation [SD]%), similar at 6 mGy (1.6 ± 1.5 [SD]%) and lower at 1.8 mGy (-17.8 ± 2.2 [SD]%). For both inserts, f50 values were higher with PCCT than DSCT at 11- and 6 mGy for all keV levels, except at 6 mGy and 40 keV. d' values were higher with PCCT than with DSCT at 11- and 6 mGy for all keV and both simulated lesions. Similar d' values to those of the DSCT at 11 mGy, were obtained at 2.25 mGy for iodine insert at 2 mg/mL and at 0.96 mGy for iodine insert at 4 mg/mL at 40 keV. CONCLUSION: Compared to DSCT, PCCT reduces noise magnitude and improves noise texture, spatial resolution and detectability on VMIs for all low-keV levels.

16.
Neuroradiology ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38514472

RESUMO

PURPOSE: We investigated whether the quality of high-resolution computed tomography (CT) images of the temporal bone improves with deep learning reconstruction (DLR) compared with hybrid iterative reconstruction (HIR). METHODS: This retrospective study enrolled 36 patients (15 men, 21 women; age, 53.9 ± 19.5 years) who had undergone high-resolution CT of the temporal bone. Axial and coronal images were reconstructed using DLR, HIR, and filtered back projection (FBP). In qualitative image analyses, two radiologists independently compared the DLR and HIR images with FBP in terms of depiction of structures, image noise, and overall quality, using a 5-point scale (5 = better than FBP, 1 = poorer than FBP) to evaluate image quality. The other two radiologists placed regions of interest on the tympanic cavity and measured the standard deviation of CT attenuation (i.e., quantitative image noise). Scores from the qualitative and quantitative analyses of the DLR and HIR images were compared using, respectively, the Wilcoxon signed-rank test and the paired t-test. RESULTS: Qualitative and quantitative image noise was significantly reduced in DLR images compared with HIR images (all comparisons, p ≤ 0.016). Depiction of the otic capsule, auditory ossicles, and tympanic membrane was significantly improved in DLR images compared with HIR images (both readers, p ≤ 0.003). Overall image quality was significantly superior in DLR images compared with HIR images (both readers, p < 0.001). CONCLUSION: Compared with HIR, DLR provided significantly better-quality high-resolution CT images of the temporal bone.

17.
Abdom Radiol (NY) ; 49(4): 1084-1091, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38416165

RESUMO

PURPOSE: To determine if hepatic and splenic perfusion parameters are useful in identifying severe portal hypertension (SPH). METHODS: The study enrolled 52 patients who underwent perfusion CT scan within one week before the hepatic venous pressure gradient (HVPG) measurement. A commercial software package was used for post-processing to generate hepatic and splenic perfusion parameters. Correlations were assessed using Pearson and Spearman rank correlation coefficients. Logistic regression was used to screen predictive parameters of SPH. The cut-off values of parameters for severe portal hypertension were calculated, as well as the sensitivity and specificity. RESULTS: There was a significant difference between SPH and non-severe portal hypertension (NSPH) in blood volume of liver (BVLiver), hepatic arterial fraction (HAF), hepatic arterial perfusion (HAP), portal venous perfusion (PVP), mean slope of increase in spleen (MSISpleen), BVSpleen, blood flow of spleen (BFSpleen), BVSpleen/Liver, and BVSpleen/Liver(P) (p < 0.05). The Spearman correlation coefficient was - 0.541 (p < 0.001) between BVSpleen/Live and HVPG and - 0.568 (p < 0.001) between BVSpleen/Liver(P) and HVPG. Using a BVSpleen/Liver value of 0.780 or BVSpleen/Liver(P) value of 1.061 as the cut-off value for the detection of SPH, the sensitivity and specificity were 94.7% and 72.7%, 100%, and 63.6% respectively. CONCLUSION: There was a moderate correlation between CT perfusion parameters BVSpleen/Liver, BVSpleen/Liver(P), and HVPG, which may be used to detect severe portal hypertension.


Assuntos
Hipertensão Portal , Baço , Humanos , Baço/diagnóstico por imagem , Baço/irrigação sanguínea , Cirrose Hepática , Fígado/irrigação sanguínea , Hipertensão Portal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Imagem de Perfusão
18.
Cancer Imaging ; 24(1): 28, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38395973

RESUMO

BACKGROUND: Surgically resected grade 1-2 (G1-2) pancreatic neuroendocrine tumors (PanNETs) exhibit diverse clinical outcomes, highlighting the need for reliable prognostic biomarkers. Our study aimed to develop and validate CT-based radiomics model for predicting postsurgical outcome in patients with G1-2 PanNETs, and to compare its performance with the current clinical staging system. METHODS: This multicenter retrospective study included patients who underwent dynamic CT and subsequent curative resection for G1-2 PanNETs. A radiomics-based model (R-score) for predicting recurrence-free survival (RFS) was developed from a development set (441 patients from one institution) using least absolute shrinkage and selection operator-Cox regression analysis. A clinical model (C-model) consisting of age and tumor stage according to the 8th American Joint Committee on Cancer staging system was built, and an integrative model combining the C-model and the R-score (CR-model) was developed using multivariable Cox regression analysis. Using an external test set (159 patients from another institution), the models' performance for predicting RFS and overall survival (OS) was evaluated using Harrell's C-index. The incremental value of adding the R-score to the C-model was evaluated using net reclassification improvement (NRI) and integrated discrimination improvement (IDI). RESULTS: The median follow-up periods were 68.3 and 59.7 months in the development and test sets, respectively. In the development set, 58 patients (13.2%) experienced recurrence and 35 (7.9%) died. In the test set, tumors recurred in 14 patients (8.8%) and 12 (7.5%) died. In the test set, the R-score had a C-index of 0.716 for RFS and 0.674 for OS. Compared with the C-model, the CR-model showed higher C-index (RFS, 0.734 vs. 0.662, p = 0.012; OS, 0.781 vs. 0.675, p = 0.043). CR-model also showed improved classification (NRI, 0.330, p < 0.001) and discrimination (IDI, 0.071, p < 0.001) for prediction of 3-year RFS. CONCLUSIONS: Our CR-model outperformed the current clinical staging system in prediction of the prognosis for G1-2 PanNETs and added incremental value for predicting postoperative recurrence. The CR-model enables precise identification of high-risk patients, guiding personalized treatment planning to improve outcomes in surgically resected grade 1-2 PanNETs.


Assuntos
Tumores Neuroendócrinos , Neoplasias Pancreáticas , Humanos , Prognóstico , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/cirurgia , Tumores Neuroendócrinos/patologia , Estudos Retrospectivos , 60570 , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia , Tomografia Computadorizada por Raios X/métodos
19.
Radiol Case Rep ; 19(4): 1634-1637, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38327559

RESUMO

We present the case of a 14-year-old adolescent boy with a history of poorly controlled asthma and a final diagnosis of a bridge bronchus associated with sling of the left pulmonary artery. Regarding the case report, we describe the characteristic findings in computerized tomography multidetector of the thorax, its classification, and the most relevant information about this malformation. Congenital malformations of the tracheobronchial tree may occur in the context of asymptomatic or symptomatic respiratory patients. These malformations may be associated with other vascular, tracheal, and syndromes with multiorgan involvement. Although most patients are asymptomatic, some of them will have nonspecific symptoms without a clear etiology or will be diagnosed incidentally during the diagnostic evaluation of other pathologies. It is important to know and recognize the normal anatomy and its variations, since radiology undoubtedly plays a fundamental role in the diagnosis and preoperative assessment of these malformations, which although they have low incidence, must be identified in a timely manner by the specialist in diagnostic images.

20.
Radiología (Madr., Ed. impr.) ; 66(1): 2-12, Ene-Feb, 2024. ilus, tab, graf
Artigo em Espanhol | IBECS | ID: ibc-229641

RESUMO

Objetivos: Valorar la relación entre el score de calcio coronario y la elección posterior del kilovoltaje según el criterio del radiólogo en un protocolo estándar (PE) de angio-TC coronaria (aTCC) para descartar enfermedad coronaria. Cuantificar la reducción de la radiación ionizante después de vincular el kilovoltaje al índice de masa corporal en un protocolo de baja dosis (PBD) con reconstrucción iterativa de modelado. Valorar la calidad de imagen y el rendimiento diagnóstico del PBD. Material y método: Las características antropométricas, el score de calcio, los niveles de kilovoltaje y los valores de dosis estimada específica para el tamaño (SSDE) y del producto dosis-longitud fueron comparados entre un grupo de 50 pacientes con PBD reclutados prospectivamente y una cohorte histórica adquirida con el PE. Estos parámetros, el número de segmentos coronarios no valorables sin y con tolerancia de fase, la atenuación y la relación señal-ruido en la aorta ascendente en el PBD fueron correlacionados con una calidad de imagen de nivel excelente según una escala semicuantitativa. El rendimiento diagnóstico por paciente fue calculado usando la revaloración clínica a los 24 meses como el método diagnóstico de referencia, incluyendo las pruebas derivadas. Resultados: En el PE existía una relación entre la presencia de calcio coronario y la elección de kilovoltajes altos (p=0,02), que desaparecía en el PBD (p=0,47). Los valores de SSDE y de DLP en el PBD fueron significativamente inferiores y presentaron menor dispersión que en el PE (9,22 mGy [RIQ 7,84-12,1 mGy] y 97 mGy*cm [RIQ 78-134 mGy*cm] contra 26,5 mGy [RIQ 21,3-36,3 mGy] y 253 mGy*cm [RIQ 216-404 mGy*cm]; p <0,001 para las comparaciones de las medianas y de las dispersiones entre ambos grupos)...(AU)


Objectives: To evaluate the relation between the coronary calcium score and the posterior choice of kilovoltage according to radiologists’ criteria in a standard coronary CT angiography protocol to rule out coronary disease. To quantify the reduction in ionizing radiation after linking kilovoltage to patients’ body mass index in a low-dose protocol with iterative model reconstruction. To evaluate the image quality and diagnostic performance of the low-dose protocol. Material and methods: We compared anthropometric characteristics, calcium score, kilovoltage levels, size-specific dose estimates (SSDE), and the dose-length product (DLP) between a group of 50 patients who were prospectively recruited to undergo coronary CT angiography with a low-dose protocol and a historical group of 50 patients who underwent coronary CT angiography with the standard protocol. We correlated these parameters, the number of coronary segments that could not be evaluated with and without temporal padding, the attenuation, and the signal-to-noise ratio in the ascending aorta in the low-dose protocol with excellent imaging quality according to a semiquantitative scale. To calculate the diagnostic performance per patient, we used 24-month clinical follow-up including all tests as the gold standard. Results: In the standard protocol, the presence of coronary calcium correlated with the selection of high kilovoltage (P=0.02); this correlation was not found in the low-dose protocol (P=0.47). Median values of SSDE and DLP were significantly (P<0.001) lower and less dispersed in the low-dose protocol [9.22 mGy (IQR 7.84-12.1 mGy) vs. 26.5 mGy (IQR 21.3-36.3 mGy) in the standard protocol] and [97mGy*cm (IQR 78-134mGy*cm) vs. 253mGy*cm (IQR 216-404mGy*cm) in the standard protocol], respectively...(AU)


Assuntos
Humanos , Masculino , Feminino , Protocolos Clínicos , Índice de Massa Corporal , Angiografia por Tomografia Computadorizada/métodos , Antropometria , Angiografia Coronária/métodos , Exposição à Radiação , Radiologia , Serviço Hospitalar de Radiologia , Angiografia por Tomografia Computadorizada/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Manual de Segurança Radiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...